Current sensing for renewable energy

For current sensors used in grid-tied photovoltaic systems, design is ever focused on minimizing the cost per watt in an effort to deliver the best possible return on investment in solar energy

With increasing concerns about the global demand for energy and the overall expansion of environmental awareness, designers for power electronics applications are under constant pressure to improve efficiency. The advent of the Smart Grid, Plug-in Hybrid Electric Vehicles (PHEV), and full Battery Electric Vehicles (BEV), as well as grid-tied photovoltaic (PV) and other grid-tied renewable energy systems, requires development of high-efficiency power inverters. Usually, higher efficiency is associated with higher application cost and reduced performance.

True advances in technology enable improved efficiency while maintaining or improving upon cost and performance. For example, as the cost of microprocessors continues to drop, more advanced control algorithms can be cheaply embedded in applications where simplistic, inefficient, and poorly performing analog control was previously the norm. With this trend continuing, the limiting factor for performance and cost is shifting to the numerous sensors required for advanced control algorithms.

For current sensors used in grid-tied photovoltaic systems, design is ever focused on minimizing the cost per watt in an effort to deliver the best possible return on investment in solar energy (Fig. 1 ). 

 farc_allegro_oct2013_Fig 1_lres

Fig. 1: Current sensors are needed throughout the grid-tie systems for control of the converters and inverters, optimization of power extraction from solar panels, and fault detection for safety.

PV systems

For a grid-tied photovoltaic system, the conversion of energy from solar panels is usually done in two stages. First, a dc/dc converter is used both to convert the voltage from the panel or array to something close to the grid voltage, as well as to maximize the power extracted from the panels. Then, an inverter is used to convert from dc to ac and sync it up with the grid. There is no standard or widely agreed upon topology for any of these stages or systems as a whole, as each conversion system is usually designed in their entirety by one manufacturer; each stage is designed and optimized to work most efficiently with the other stages in an attempt to yield the highest overall efficiency. Regardless of the system design, current sensors play an important role in the control of the different stages of conversion, directly impacting the efficiency and effectiveness of the system.

Conversion and MPPT

In any photovoltaic conversion system, maximum power point tracking (MPPT) is an important aspect, enabling maximum energy extraction from an array. The efficiency of MPPT algorithms is greatly impacted by the sensors used for feedback. The basis of MPPT is that at any given time the I-V curve of each solar panel indicates the optimum operating point, or maximum power point (MPP, see Fig. 2 ). However, it is also evident that the IV curve and, subsequently, the MPP will change with both irradiance and temperature. It is the MPPT algorithm's job to constantly search for the MPP. 

farc_allegro_oct2013_Fig2_lres  

Fig. 2: The graph above shows how I-V curves change with both irradiance and temperature. Subsequently, the maximum power point (MPP) will change, and the tracking algorithms must determine the new MPP.

There are many different MPPT algorithms; however, most operate by measuring power — either at the input or output of the dc/dc converter stage — and changing the operating point of the converter to move along the IV curve to find the MPP. These algorithms all essentially perform some form of gradient ascent, estimating the slope of the current-(or voltage)-versus-power curve and using that to determine how to change the operating point. If the slope is positive, the operating point is increased; if negative the operate point is decreased.   

One of the most common algorithms is called perturb and observe. Here, the power from the solar panel or array is measured, the operating point is changed, and the power is measured again. If the power goes up, one keeps moving the operating point in the same direction; if the power goes down, one moves the operating point in the opposite direction. This results in tracking of the MPP, though it also results in steady-state oscillation around the MPP. To minimize the steady-state oscillation, the size of the steps can be reduced.  However, the update rate must be increased to maintain the tracking speed.

Ultimately, the limiting factor in tracking efficiency will be the noise in the power measurement. This is because continuing to decrease the step size means that one will run into the noise of the power measurement, which will confuse the algorithm and lead to oscillations around the MPP. All “hill-climbing” algorithms which includes perturb and observe, as well as incremental conductance, or ripple correlation control, to name a few, will be fundamentally limited by the noise in the power measurement sensors.

For most MPPT applications, the bandwidth needed in a current sensor is in the hundreds of hertz, meaning one will typically filter or average the output of the sensor to decrease the noise and improve tracking efficiency. However, sensors are necessary if using ripple-correlation control, which uses the inherent input ripple of the dc/dc converter to measure the slope of the voltage vs. power curve.

The inverter stage   

In a photovoltaic system, the dc/dc converter stage of is typically followed by an inverter stage, which ties the output of the system to the grid (see Fig. 1 ). This signal must be compliant with the utility system's requirements, including proper synchronization to the grid and low total harmonic distortion (THD). Current sensors are needed in the systems' control loops to ensure proper connection to the grid. The sensors must not only accurately measure both ac and dc currents, they must have high dynamic performance: very fast response times are needed to react quickly to any change in the grid, shutting off or disconnecting the system in the case of a short circuit (that is, ground fault) or loss of the grid connection (anti-islanding). The high output bandwidth is also needed to measure high-frequency ac currents and harmonics at different points in the system.

For inverters without a transformer or with a high-frequency transformer, sensors must exhibit low offset drift with temperature (high accuracy) so as to control the dc component in the ac current fed to the grid. Regulations differ from country to country for this electrical dc current limit, but generally it is small: on the order of tens to hundreds of milliamps.

In a typical inverter configuration, there are a number of locations where a current sensor might be used (see Fig. 3 ). While one could use an expensive, high-precision current sensor, it is also possible to achieve high accuracy by using one or more economical current sensor ICs in conjunction with the microprocessor already necessary for the system. The on-board intelligence can be used to calibrate out offset error. For example, there will be periods of time where sensors 2 and 3 will have no current flowing through them. One can sample the output of the sensor ICs during those periods and use a moving average filter to generate an internal zero amperage output reference for that sensor IC, dramatically decreasing the offset drift, limited only by the noise and size of the averaging filter.

farc_allegro_oct2013_Fig3_lres

Fig. 3: Multiple current sensors are seen in this diagram of a typical inverter configuration. For simplicity, filter components are not shown; however, they will usually be placed on either side of the transformer (if one is used at all), with designers often using the leakage inductance of the transformer as part of the filter.

For example, using a ACS710-6BB (see sidebar , “Current Sensor Solutions) sampling at 20 kHz (with proper filtering to avoid anti-aliasing), and averaging 2,000 samples (over many different durations of zero current flowing through the sensor IC), can achieve a resolution of 1.5 mA to which the zero-current offset can be calibrated. When this calibrated sensor is put in series with another sensor, such as sensor 4, the relationship between the two can be determined, calibrating sensor 4 will provide a very low offset drift over temperature, allowing it to be used for sensing the dc component of the current fed to the grid. Ultimately, there are a number of similar ways in which one can calibrate current sensors dynamically in inverter applications depending on the particular topology and control scheme chosen, and if one is able to do this, the cost and space savings could be significant.

SIDEBAR: Current sensor solutions  

Allegro MicroSystems has developed a family of fully integrated, current sensor ICs suited for MPPT applications (see figure ). Low-noise performance of the Hall IC output signal is accompanied by >120 kHz bandwidth operation and analog output response times of less than 4 μs.

farc_allegro_oct2013_Fig4_lres

 

Each of Allegro's current sensor ICs contains a precision Hall-effect element coupled to a low-offset, high-accuracy amplifier. The Hall element and amplifier are chopper-stabilized to enhance accuracy and offset-drift performance. 

For most MPPT applications, the bandwidth needed is much lower than 120 kHz, meaning one will filter or average the output of the sensor to decrease the noise and improve tracking efficiency. However, high- bandwidth sensors are necessary if one is using ripple-correlation control, which uses the inherent input ripple of the dc/dc converter to measure the slope of the voltage-vs-power curve.

For low- to medium-current MPPT applications, such as micro-inverters, the ACS710-6BB provides a balance between accuracy, size, and cost. Its advantages for current sensing in MPPT applications include:

1. Low power loss.
2. Low noise of around 77 μA/√Hz rms and a filter pin with which one can easily add a low-pass filter of any corner frequency to the output.
3. High isolation.
4. High current measurement of up to 40 A continuous at 85°C, withstanding current pulses in excess of 200 A for 10 ms or more.

The ACS710 also offers programmable fault thresholds, which are useful for overcurrent protection requirements, with a typical response time of less than 2 μs, which is necessary for IGBT protection. While the Allegro current sensor ICs meet the very high accuracy needs of many inverter applications, in-circuit calibration may be required to meet the dc offset accuracy requirement for grid connection.  