BY SEBASTIEN KEMPTER
Engineering Team Project Leader
Fischer Connectors
www.fischerconnectors.com
Q: When does weather impact the design of your device?
A: When you are determining the operating voltage of your connector solution.
To many, that answer will come as a surprise. Unlike most product specifications, operating voltage is not an intrinsic characteristic of a connector. Because voltage is affected by environmental conditions such as humidity and air pressure, and is subject to safety requirements that are often field-specific, it is often difficult to determine the actual voltage that the connector can safely carry.
This article will walk you through the conditions that impact operating voltage, so that you can be better informed to specify connectors that will work as expected in your unique, rugged environments.
Voltage ratings are often of crucial importance because they are safety-related. But accommodating the proper voltage is not always a straight-forward determination when it comes to connectors in rugged environments. Unlike most product specifications, operating voltage is not an intrinsic characteristic of a connector because voltage is affected by environmental conditions such as humidity and air pressure, as well as safety requirements that are often field-specific.
In addition to weather conditions, an engineer must plan for materials to degrade over time in tough conditions. The guidelines in this paper will help equipment manufacturers identify considerations for selecting an adequate connector solution based on general guidelines.
Before you begin, however, it is important that you identify whether specific regulations or standards exist for the equipment being designed, as they must be considered and incorporated into the device and connector solution as a priority.
Common definitions
To begin, we need to establish the meanings of three terms: breakdown voltage, test voltage, and operating voltage.
Breakdown voltage is a characteristic that defines the maximum voltage difference that can be applied before a disruptive discharge occurs between mutually insulated portions of a connector, or between insulated portions and ground. Breakdown voltage is measured in a destructive test.
Test or withstanding voltage is the voltage level at which the connector is tested during a qualification test. According to IEC 60512-4-1, the test shall last 1 minute and no flashover or breakdown is allowed. This value represents the upper physical limit, and is sometimes used as a basis to calculate operating levels when predefined safety factors are established.
In theory, test voltage may be stated as high as it is tested, provided the conditions of the standard are met. Practically, however, test voltage is usually set at 75% of breakdown value (as defined for examples in EIA-364-20 and former MIL-STD-1344 method 3001). Fischer Connectors always applies this 75% ratio; so the resulting test voltage values cited are reliable even when breakdown values exhibit the large scatter typical in high-voltage testing. (See Fig. 1 .)
Fig. 1: Test voltage is usually set at 75% of the nominal breakdown voltage.
Operating voltage is the voltage under which the connector will actually work in the equipment over the normal expected lifetime and in typical environmental conditions. As we will see, this value depends both on connector design and on the specific operating environment.
Often, significant scatter is observed in breakdown testing, because the breakdown mechanism is naturally triggered by instabilities. Breakdown voltages determined at various locations with different equipment frequently result in up to 10% differences. Such differences in breakdown voltage do not show evidence of differences between the test samples.
The overall performance of any electrical connector is typically determined by the spacing of the contacts (air gap), the distance along insulating components (creepage distance), and of course, by the choice of the insulating material. In most general-purpose connector designs, the short-term performance is driven by the insulating performance of the surrounding air. In the long term, the physical properties of the insulating material are important.
Determining operating voltage
The operating voltage as defined above must be applicable to the device over the entire lifetime of the equipment and under typical working conditions. This means that you need to plan for the possibility of a long-term degradation of the insulating materials under variable aggressive environmental influences. This is typical for all kinds of electrical devices, and has led to the development of generic standards providing adequate guidelines.
For connectors in common applications, IEC60664 is particularly recommended. (IEC regulations cited are available for purchase at www.iec.ch.) This specification uses creepage distance (the shortest distance between two conductors as measured along the insulation that separates them) instead of test voltage as a basis for calculating the operating voltage, taking into account the above-mentioned long-term effects. It is similar to German VDE 0110; typical applications are classified in insulation groups depending on their exposure to pollution. The use of IEC60664 is recommended in general multipole connector specifications, unless other more specific standards or regulations are applicable to the design. For example, IEC 60601 provides adequate special guidelines for medical devices.
Other standards recommend a calculation using the test voltage as a basis with the application of a safety factor: for example, BS 9520, EIA-364-20, and former MIL-STD-1344 method 3001. These methods takes into account the measured test voltage of the connector; however, they do not take into consideration either long-term environmental effects or the specific behavior of different insulator materials. These methods can be recommended for cases where the connector “on-time” or duty cycle is low, combined with little exposure to environmental factors, for example, scientific instruments or similar equipment. Fischer Connectors provides test voltage values in the general catalog and in some product specifications.
Fig. 2 shows a comparison of both design methods. No precise rule can be given for the selection of the best method to determine operating voltage. Thorough study of the specific application, the operating conditions, and relevant safety rules is essential for the designer.
Fig. 2: A comparison of BS 9520/EIA-364-20, which uses calculations based on breakdown and test voltages, versus IEC60664, which is based on creepage distance and airgap.
Frequency effects
Both methods described in Fig. 2 are valid for conventional dc or low-frequency ac conditions. At high frequencies, additional physical effects in the insulating material may significantly affect the performance of the connector. Of course, the connector cannot be considered as an isolated element; in such critical situations, the response of the entire system including cables and other devices should be evaluated.
At low frequencies, electrical charges on the insulator surface will move according to their relative freedom of movement; time within a cycle is sufficient to relax the local accumulated charges. At high frequencies (typically above the kHz range), the simultaneous displacement of these charges leads to the well-known corona effect or partial discharge, accelerating the breakdown.
High-frequency pulsed signals are particularly critical, as they exhibit very high ∂u/∂t values (Fig.3 ). No specific guidelines can be given to adapt operating voltage to these conditions which require individual testing. But as a rule of thumb, based on IEC 60664 data, one can estimate that a derating down to 50% may be needed for critical kHz frequencies.
Fig. 3: High-frequency pulsed signals in the format shown here are particularly critical, as they exhibit very high ∂u/∂t values. Due to a phenomenon refered to as a Pulse Wave, such signals are known to generate discharges in connectors well below dc operating limits.
Effect of air pressure
The insulation properties of all gases, including air, are strongly influenced by their pressure. This pressure directly determines the density of the gas, and therefore the actual breakdown voltage. Connectors and other similar devices using air as an insulator must be designed to take this fact into account. Furthermore, correction factors must also be applied to the connector’s normal voltage rating for those applications in which the connector is expected to operate at non-standard
atmospheric pressure.
The breakdown voltage of a connector in a gas will decrease as the pressure decreases. This phenomenon is called Paschen’s Law, and the curves are of empirical origin (Fig.4 ). Specialized high-voltage literature can provide more details and data for specific gases, for example Traité d’Electricité XXII — Haute Tension by Aguet and Ianovici, Swiss Federal Institute of Technology, Lausanne.
Fig. 4: Curve for breakdown voltage based on Paschen's Law.
Paschen’s law is essential in vacuum applications; the graph provided herein can assist in determining the correct parameters of the connector’s operation, but thorough testing is essential. It is also recommended that power be switched off during the degassing phase of vacuum equipment to avoid exposure of the connector to the most critical low-insulating atmosphere.
At elevated altitudes, the physical phenomena influencing breakdown voltage are generally similar to those in a partial vacuum; however, special attention should be paid to the fact that specific atmospheric parameters, like temperature and moisture, which also affect dielectric behavior, are of an uncontrolled nature.
Correction factors based on altitude/air pressure
Altitude |
Typical air pressure |
Correction factor for |
2,000 |
800 |
1.00 |
3,000 |
700 |
1.14 |
4,000 |
620 |
1.29 |
5,000 |
540 |
1.48 |
6,000 |
470 |
1.70 |
7,000 |
410 |
1.95 |
8,000 |
355 |
2.25 |
9,000 |
305 |
2.62 |
10,000 |
265 |
3.02 |
Engineers determining the operating voltage of a connector must take the operating environment into consideration, including the impact of the environment on cables and insulating material. They must do this while maintaining all safety features and functions required by specific regulations or standards for their devices.